1.
Chinese Journal of Pathology ; (12): 510-514, 2019.
Article in Chinese | WPRIM | ID: wpr-810744

ABSTRACT

Objective@#To analyze the clinicopathological features of pseudotumor-like tissue around aseptic joint arthroplasty and aseptic lymphocytic vasculitis-associated lesions (ALVAL) scores. The characters of wear granules were observed.@*Methods@#Total 122 cases were retrieved from the surgical pathology files between May 2015 and August 2018 in the department of pathology in Beijing Jishuitan Hospital, which included the knee joint arthroplasty (10 cases) and hip arthroplasty (112 cases). There were 62 females and 60 males. Patients′ age ranged from 29 to 86 years (mean 56 years). The pseudotumor-like tissue around aseptic joint arthroplasty were stained with HE and analyzed by two ALVAL score systems. The characters of wear granules were observed by light microscope and polarized light.@*Results@#The cohort included 62 females and 60 males. Patients′ age ranged from 29 to 86 years (mean 56 years). Compbell-ALVAL system includes synovial lining,inflammatory infiltrate and tissue organization. The scores were: low (0-4): 18cases; moderate (5-8): 101 cases; high (9-10): 3 cases. Oxford-ALVAL system only evaluated the inflammatory infiltrate,and the scores were:0 grade:56 cases; 1 grade:51 cases; 2 grade: 12 cases; 3 grade:3 cases. Cases with high score in the Compbell-ALVAL system were concordant with the 3 grade of the Oxford-ALVAL system. Under light microscope,the metal particles were small black granules; the polyethylene fibers were needle-like and easily visible in polarized light. The polymethylmethacrylate showed clear spaces because of particle melting.@*Conclusions@#The Compbell-ALVAL scoring system is based on the histologic analysis of pseudotumor-like tissue around aseptic joint arthroplasty, and the Oxford-ALVAL scoring systems is based on lymphocytic response. The wear particles could be differentiated by the features in the light microscope.

2.
Chinese Journal of Pathology ; (12): 940-944, 2019.
Article in Chinese | WPRIM | ID: wpr-800344

ABSTRACT

Objective@#To evaluate the role of histologicalpathology in the diagnosis of periprosthetic joint infection.@*Methods@#A total of 145 cases of joint arthroplasty during October 2017 and October 2018 from Beijing Jishuitan Hospital were collected. There were 23 cases of infection, including knee joint arthroplasty (12 cases) and hip arthroplasty (11 cases). There were 17 females and 6 males. Patients′ age ranged from 39 to 76 years (mean 63 years). The infection was diagnosed if there were >5 neutrophils per high power field in at least 5 high power field. The permanent sections were examined twice separately by two pathologists, and the interval time of histologic examination was at least two weeks. Sensitivity (SE), specificity (SP), positive predictivevalue (PPV), and negative predictive value (NPV) were calculated. The consistency evaluation of histologic examination of two pathologists was calculated by Kappa analysis.@*Results@#The neutrophil cells could locate scattered or focally in the synovium tissue of periprosthetic joint infection. Somewhere, the infiltration of vessel and the perivascular distribution could also exist. Opportunity coincidence rate between two pathologists was 91.3% (Kappa=0.817). The results showed that SE was 60.9%, SP was 100.0%, NPV was 93.1%, PPV was 100.0%.@*Conclusions@#The presence of polymorphonuclear cells in histologic examination is correlated with infection. There was high consistency between histologic examination and clinical diagnosis of joint arthroplasty.

3.
Chinese Journal of Orthopaedics ; (12): 914-920, 2017.
Article in Chinese | WPRIM | ID: wpr-611999

ABSTRACT

Objective To evaluate the clinical outcome of Vancouver B2 and B3 periprosthetic femoral fractures treated with uncemented modular stems.Methods From September 2011 to April 2014,Twenty-four patients (12 males and 12 females,with the average age 63 years,ranging from 28 to 85 years) with periprosthetic femoral fractures (16 Vancouver B2 and 8 Vancouver B3) were treated with uncemented modular stems.Revision arthroplasty was conducted in all cases by using modular stems with 12 cerclage wirings and 11 great trochanter claw plates.One patient was treated with revision arthroplasty without additional fixations.Extended trochanter osteotomy was performed on 11 patients.Cortical strut allograft was used in 9 patients with severe femoral bone loss.Intraoperative complications including vascular or nerve injury and systemic complications including cardiovascular events,cerebrovascular events and deep vein thrombosis were recorded.Severe postoperative complications such as nonunion,re-fracture,periprosthetic joint infection and dislocation were recorded.The clinical outcome was evaluated by Harris score,Visual Analogue Score and Parker Mobility Score.The radiological outcome was taken to observe the healing status,stem subsidence and stability of the prosthesis.Results Two patients were lost to follow-up.Twenty-two patients were clinically followed-up.Radiological data was recorded in 16 patients.The average follow-up was 33 months (range,12-68 months).All fractures healed within 6 months.The average Harris score improved from 4.0± 1.1 preoperatively to 78.8± 16.2 postoperatively (t=-20.195,P=0.000).The mean Parker Mobility Score improved from 0.5±0.9 preoperatively to 7.0± 1.8 postoperatively (t=-14.835,P=0.000).The mean Visual Analogue Score decreased from 6.4± 1.2 preoperatively to 2.0± 1.5 postoperatively (t=10.879,P=0.000).No nonunion,infection or dislocation was found.One patient underwent re-operation because of re-fracture.Eight mm of prosthesis subsidence was observed in one case at 3 months postoperatively,and reached stable fixation at 6 months postoperatively without further subsidence.Conclusion Uncemented modular stems can achieve distal fixation and implant stability of periprosthetic femoral fractures while retaining optimal biomechanics of the hip.Assisted by femoral reconstruction techniques such as extended trochanter osteotomy,cortical strut allograft,great trochanter claw plates and cerclage wiring,revision arthroplasty using uncemented modular stems could realize optimal outcomes in treating Vancouver B2 and B3 periprosthetic femoral fractures.

4.
Chinese Journal of Tissue Engineering Research ; (53): 8331-8336, 2013.
Article in Chinese | WPRIM | ID: wpr-441050

ABSTRACT

BACKGROUND:Crowe IV developmental dysplasia of the hip is rarely seen clinical y. However, when treated with routine total hip arthroplasty, severe deformities in the bone and soft tissue can lead to high rate of operation failure and increased occurrence of complications. Total hip arthroplasty in combination with subtrochanteric osteotomy may be an option to resolve this problem. OBJECTIVE:To retrospectively analyze the clinical outcome and safety of Crowe IV developmental dysplasia of the hip treated by the combination of total hip arthroplasty and subtrochanteric osteotomy in 17 cases. METHODS:Twenty-one hips (17 cases) of Crowe IV developmental dysplasia of the hip treated by the combination of total hip arthroplasty and subtrochanteric osteotomy were retrospectively analyzed and fol owed for at least 2 years from January 2006 to June 2011. Complications, hip function, and radiological changes were evaluated. RESULTS AND CONCLUSION:The mean fol ow-up period was (48.0±20.5) months. Harris’s score was increased postoperatively (P<0.05). The main complains were lower limb length discrepancy, difficulty in standing up from squatting, muscle weakness, and soft tissue tightness. One greater trochanter fracture occurred and was fixed by hook plate fixation. There were four femoral shaft splits treated by cerclage. One patient represented with femoral nerve palsy and got partial recovery until the latest fol ow-up. There was no deep infection, dislocation or prosthesis loosening. Crowe IV developmental dysplasia of the hip could be effectively treated by total hip arthroplasty in combination with subtrochanteric osteotomy, which requires high surgical techniques to control the complications. Further fol ow-up is required for long-term results.

5.
Chinese Journal of Orthopaedics ; (12): 273-277, 2013.
Article in Chinese | WPRIM | ID: wpr-432167

ABSTRACT

Objective To investigate normal patellar morphology,then to explore its possible instructive significance in the design of patella prosthesis for Chinese people and in the process of resurfacing patella.Methods CT scan examinations were performed in 60 normal knees (left or right knee was selected randomly; scan region,from half proximal tibia to half distal femur) of 60 healthy Chinese adults (32 males,28 females; age range,18-54 years; mean age,33.7 years),then mimics software was used to reconstruct the 3-D morphology of each patella and new coronal and sagittal planes were created.Each patella's height,width,thickness,the position of the dome,the ratio of height/width,and the residual thickness after patella was resected at the level of the subchondral bone of the lateral facet during the stimulating process of patella resurfacing were measured or calculated.Results Patella of Chinese male:height 31.95±2.77 mm,width 45.02±2.70 mm,thickness 22.38 ±1.63 mm,the residual thickness after patella was resected 13.18±1.62 mm; Patella of Chinese female:height 28.72±2.17 mm,width 39.57±2.57 mm,thickness 19.88±1.36 mm,the residual thickness after patella was resected 11.20±1.20 mm.Significant differences existed between male and female for all the above four parameters.Patella of Chinese male:the ratio of width/height 1.42 ±0.11,the position of the dome (medial 42.9%); Patella of Chinese female:the ratio of width/height 1.38±0.10,the position of the dome (medial 42.6%).No significant differences existed between male and female for the above two parameters.Conclusion The patella of Chinese people is small,thin and slim,especially in Chinese female.These findings should be considered in selecting or designing patella prosthesis to fit the Chinese people.For Chinese female,more attention should be paid to keep appropriate residual thickness after the patella was resected during the process of patella resurfacing.

6.
Chinese Journal of Trauma ; (12): 1012-1016, 2011.
Article in Chinese | WPRIM | ID: wpr-422849

ABSTRACT

Objective To observe the efficacy of total ankle replacement in treatment of osteoarthritis of ankle joint.Methods Between October 1999 and October 2006,42 patients with ankle osteoarthritis were admitted in Beijing Jishuitan Hospital.All the patients met surgical indications and were performed total ankle replacement with S.T.A.R.system ( Scandinavian Total Ankle Replacement) (Waldemar Link,Hamburg,Germany).The pain in patients,motion and function of joint were evaluated pre- and post-operatively according to Kofoed scoring system,and the efficacy was evaluated with the Mayo'evaluation criteria of total ankle replacement.Results According to Kofoed scoring system,the postoperative situation was obviously superior to the preoperative in pain,motion and function of joint(P < 0.05 ),and the excellent and good rate was 90.32%.While,the excellent and good rate was 87.5%with the Mayo' evaluation criteria of total ankle replacement.Conclusion Total ankle replacement,which can relieve pain,restore ankle function and improve ankle activity,provides another effective method for the patients who need ankle arthrodesis.

7.
Chinese Journal of Trauma ; (12): 437-440, 2008.
Article in Chinese | WPRIM | ID: wpr-400167

ABSTRACT

Objective To discuss the characteristics and clinical results of rotating platform high flexion(RDHF)total knee replacement TKR. Methods A total of 61 patients(78 knees)including 13males(15 knees)and 48 females(63 knees)at age range of45-79 years(mean 64.3 years)were treated with Sigma(RP-HF)rotating platform high flexion total knee replacement.Osteoarthritis was found in 56patients and rheumatoid arthritis in 5.By medial parapatella approach,denervation and facet repair of the patella were done,without replacing them. Results All 78 knees were followed up for 3-16 months (mean 10.5 months).the X-ray film demonstrated no prosthesis loosening,patella dislocation or subluxation.According to the knee society scoring system,the preoperative score was 48 points(33-72 points)and the knee functional score was 41 points(28-63 points)on average.After surgery,the knee score was 97points(88-100 points),the functional score 96 points(84-99 points),and the range of motion(ROM)130.(110.-150.)on average.No spin-out or infection were detected. Conclusions The Sigma RP-HF knee system provides sufficient contact area.full range of patella locus and sufficient axial rotation,which helps reach a stable and durable high flexion performance.Our short-term clinical follow up result is good but the advantages of low wear and longevity of the Sigma RP-HF prosthesis still need further study.

8.
Orthopedic Journal of China ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-547727

ABSTRACT

[Objective] To study the application and clinical result of extended trochanteric osteotomy in hip joint revision.[Methods]Thirteen hips in 13 patients who were treated with extended trochanteric osteotomy in hip joint revision from 2003 to 2007 were followed-up for an average time of 32.3 months.The revision reasons,Harris score,osteotomed length,and the oeteotomed union time were analyzed.[Results]The average preoperative Harris score of all patients was 38(24~68),the average postoperative Harris score was 77(57-100),with the improvement of 39 points.The average osteotomed length from the tip of great trochanter to distal osteotomy site was 12.4 cm(9~15.1 cm).The osteotomy sites were healed in 11 patients at 3 months and 2 patients at 6 months after operation.[Conclusion]Extended trochanteric osteotomy is useful in hip joint revision.After osteotomy femoral prosthesis and cement could be taken out easily,and the osteotomy site could be healed easily.